Technological Data Sheet
Waterproof and Heat Resistance Coatings | ||||
# | Inspection Items | Standard | Inspection Result | |
1 | Condition in Container | Without lumps after mixing | Meets the standard | |
2 | Constructability | Easy to apply for second time | Meets the standard | |
3 | Film Appearance | Normal | Meets the standard | |
4 | Low Temperature Stability | Without lumps and separation | Meets the standard | |
5 | Drying Times | ≥ 2 Hours | 2 Hours | |
6 | Alkali Resistance | 48 Hours normal | Meets the standard | |
7 | Water Tolerance | 96 Hours normal | Meets the standard | |
8 | Washability | 2000 times | Meets the standard | |
9 | Solar reflectance ratio (white) | ≥ 0.83 Hours normal | 0.85 | |
10 | Hemisphere reflection | ≥ 0.85 | 0.88 | |
11 | Exposed Surface temperature control | Upto 25oC | 20oC | |
12 | Water tank temperature control | Upto 10oC | 8oC | |
13 | Artificial Climate ageing resistance (400 Hours) | Appearance | Without cracking, peeling, and chalking |
Meets the standard |
Chalking | ≤ 1 | 0 | ||
Conclusion: According to JC/T1040-2007 « Building exterior surface heat reflection and insultation coatings » all the inspection items are qualified. |